Client
Industrial Fans Manufacturer
Application
Fan Performance and Type Testing
Date
2016
Introduction
Industrial fans play a crucial role in various applications, from ventilation systems to industrial processes. Their performance and efficiency must be tested to meet requirements and optimize reliability. Precise data acquisition and analysis of key performance values are essential to ensure operational availability and optimize energy efficiency.
Challenge
Performance testing of industrial fans is challenging because of the number of different values that must be measured simultaneously. Parameters such as electrical power, air pressure, temperature, noise level and rotation speed must be accurately recorded. In addition, strict standards such as ISO 5801 must be adhered to. Integrating all these measurements into an efficient, user-friendly system is essential to ensure reliability and optimize overall system performance.
OUR SOLUTION
Performance Testing of Industrial Fans
Solfas provides a customized mobile solution that can be easily integrated into various fan test setups.
The unit provides accurate measurement of 3-phase power, winding resistance, temperature, differential pressure, sound level and speed with calibrated instruments.
The system is remotely controlled from a PC by our custom data logger software, which records and displays all measurement data. Easy export to CSV and Excel ensures seamless data analysis and evaluation.
Highlights
Performance Testing of Industrial Fans
Features
For the highest level of efficiency and convenience in fan testing
Customized Data Logger Software
Customised and flexible software efficiently captures all required measurements.
Export to CSV and Excel
The data can be easily exported to CSV and Excel. This enables simple customized evaluation and documentation.
Remote Control
The system and all instruments are fully remote controlled for convenient operation from the desk or control room.
Online Update and Trigger
Continuous updating of export data during measurement and live calculation of performance values.
Networking with Ethernet and WIFI
For easy integration into vaious test setups and mobile use of the system.
PC Control
Full system operation can be managed directly from PC.
Measurement Values
For Performance Testing of Industrial Fans
3-Phase Voltage, Current and Power
All of the 3-phase motor’s electrical data such as voltage, current and power are precisely measured.
Differential Pressure
The differential pressure between the inlet and outlet is measured to determine the performance of the fan.
Sound Level
Sound level measurements, frequency analysis and vibration measurements
Rotation Speed
Simple speed measurement with laser sensor and reflective marker.
Temperature
Connection options for various temperature sensors such as PT100, thermocouples and others.
Winding Resistance
The cold resistance and the cooling curves after the heat run can be measured accurately in all windings of the motor.